H3C新華三-LSPM1FANSA-S5560-S5130
價格
訂貨量(個)
¥500.00
≥1
¥450.00
≥20
¥400.00
≥40
店鋪主推品 熱銷潛力款
莸莾莹获莾获莹获莸获莸
在線客服
LSPM1FANSA | S5560 以太網交換機風扇模塊(端口側出風) |
LSPM1FANSB | S5560 以太網交換機風扇模塊(電源側出風) |
LSWM1STK | SFP+電纜0.65m |
LSWM2STK | SFP+電纜1.2m |
LSWM3STK | SFP+電纜3m |
LSTM1STK | SFP+電纜5m |
LSWM1QSTK0 | 40G QSFP+ 1m電纜 |
LSWM1QSTK1 | 40G QSFP+ 3m電纜 |
SFP-GE-SX-MM850-A | 光模塊-SFP-GE-多模模塊-(850nm,0.55km,LC) |
SFP-GE-LX-SM1310-A | 光模塊-SFP-GE-單模模塊-(1310nm,10km,LC) |
SFP-GE-LH40-SM1310 | 光模塊-SFP-GE-單模模塊-(1310nm,40km,LC) |
SFP-GE-LH40-SM1550 | 光模塊-SFP-GE-單模模塊-(1550nm,40km,LC) |
SFP-GE-LH80-SM1550 | 光模塊-SFP-GE-單模模塊-(1550nm,80km,LC) |
SFP-GE-LH100-SM1550 | 光模塊-SFP-GE-單模模塊-(1550nm,100km,LC) |
SFP-GE-LX-SM1310-BIDI | 光模塊-SFP千兆BIDI光模塊-TX1310/RX1490,10km,LC |
SFP-GE-LX-SM1490-BIDI | 光模塊-SFP千兆BIDI光模塊-TX1490/RX1310,10km,LC |
SFP-GE-T | 電模塊-SFP-GE-(RJ45) |
SFP-XG-SX-MM850-A | SFP+ 萬兆模塊(850nm,300m,LC) |
SFP-XG-LX220-MM1310 | SFP+ 萬兆模塊(1310nm,220m,LC) |
SFP-XG-LX-SM1310 | SFP+ 萬兆模塊(1310nm,10km,LC) |
SFP-XG-LX-SM1310-E | SFP+ 萬兆模塊(1310nm,10km,LC) |
SFP-XG-SX-MM850-E | SFP+ 萬兆模塊(850nm,300m,LC) |
問題描述:
現場所有的S5560系列交換機風扇信號燈黃燈閃爍,前面板SYS信號燈紅色常亮。
現場環境:
檢查交換機風扇配置信息發現交換機風扇的實際氣流方向為:Airflow Direction: Port-to-power;而配置用戶下看到風扇模塊的優選氣流方向為:Prefer Airflow Direction: Power-to-port,兩者不一致(交換機風扇反轉),導致交換機風扇狀態為:FanDirectionFault,風扇信號燈告警,交換機SYS信號燈告警。
處理:
因為風扇模塊的實際氣流方向是無法改變的,只能去改變風扇模塊的優選氣流方向和風扇實際氣流方向一致,操作步驟如下:
QIANZHI-B] [QIANZHI-B]dis fan Slot 1: Fan 1: State : FanDirectionFault //工作狀態報錯 Airflow Direction: Port-to-power //實際氣流方向 Prefer Airflow Direction: Power-to-port //優選氣流方向 Fan 2: State : FanDirectionFault Airflow Direction: Port-to-power Prefer Airflow Direction: Power-to-port
調整交換機的優選氣流方向:
[QIANZHI-B]fan prefer-direction ? slot Specify the slot number [QIANZHI-B]fan prefer-direction slot 1 ? port-to-power From port to power power-to-port From power to port [QIANZHI-B]fan prefer-direction slot 1 port-to-power [QIANZHI-B] [QIANZHI-B]dis fan Slot 1: Fan 1: State : Normal //工作狀態正常 Airflow Direction: Port-to-power //實際氣流方向 Prefer Airflow Direction: Port-to-power //優選氣流方向 Fan 2: State : Normal Airflow Direction: Port-to-power Prefer Airflow Direction: Port-to-power
修改配置后,交換機各指示燈恢復正常。