進口消聲止回閥德國洛克品牌產品優勢
價格
訂貨量(臺)
¥2100.00
≥1
店鋪主推品 熱銷潛力款
萦萫萧萬萤萦萧营萩萧营
在線客服
- 基本信息
- 品牌:德國洛克
- 型號:DE LOCKE
- 驅動方式:自力式
- 介質溫度:-5℃≈150℃℃
- 工作壓差:1.6Mpa
- 適用介質:水
- 壓力環境:常壓
- 用途:防止倒流
- 外型尺寸:中型
進口消聲止回閥德國洛克品牌產品優勢
進口消聲止回閥優點:
1、此閥可立式、臥式安裝,閥瓣升降靈活,且運行平穩、噪音底、安全、極少有故障。
2、結構合理、密封性能好。
3、耐磨損,使用壽命長。
進口消聲止回閥描述:
德國《DE LOCKE》洛克進口消聲止回閥閥瓣采用進出口兩端中心軸導向,啟閉靈活,定位準確,可水平安裝或垂直安裝,閥瓣采用彈簧加載,其快速的關閉能有效地減少水錘壓力。密封面采用O形圈彈性密封與金屬硬密封的組合密封結構,密封性能好,關閉時無噪聲。還具有體積小、重量輕、流體阻力小、結構長度小、耐疲勞、壽命長等特點。該閥門安裝于給排水、消防、暖通系統可安裝于水泵出口處,防止回水倒流,而對泵造成損壞。
進口消聲止回閥技術參數:
1、規格范圍:DN40-DN400
2、溫度范圍:-5℃≈150℃
3、壓力范圍:PN16
4、閥體材質:鑄鐵、WCB
5、閥桿材質:304/銅
6、閥蓋材質:和本體一樣
7、閥板材質:304/銅
8、連接方式:法蘭
9、適用范圍:水
Technical parameters of imported silencing check valve:
1. Specification range: dn40-dn400
2. Temperature range: - 5 ℃ ~ 150 ℃
3. Pressure range: PN16
4. Valve body material: cast iron, WCB
5. Stem material: 304 / copper
6. Valve cover material: the same as the body
7. Valve plate material: 304 / copper
8. Connection mode: flange
9. Scope of application: water
進口消聲止回閥安裝與維護:
1,本閥門通路兩端須堵塞,存在干燥通風的室內。如長期存放,應經常檢查防銹蝕。
2,安裝前應將閥門清洗干凈,并消除在運輸過程中造成的缺陷。
3,安裝時必須仔細核對閥門上的標志和銘牌是否符合使用要求。
4,升降式垂直瓣止回閥應安裝在垂直管道上。
5,升降式水平瓣止回閥應安裝在水平管道上。
6,在管線中不要使止回閥承受重量,大型的止回閥應獨立支撐,使之不受管系產生的壓力的影響。
7,安裝止回閥時,應特別注意介質流動方向,應使介質正常流動方向與閥體上指示的箭頭方向相一致,否則就會截斷介質的正常流動。底閥應安裝在水泵吸水管路的底端。
8,通式升降式止回閥應安裝于水平管路上,立式升降式止回閥和底閥一般安裝在垂直管路上,并且介質自下而*動。
9,止回閥關閉時,會在管路中產生水錘壓力,嚴重時會導致閥門、管路或設備的損壞,尤其對于大口管路或高壓管路,故應引起止回閥選用者的高度注意。
Installation and maintenance of inlet silencing check valve:
1. Both ends of the valve passage must be blocked, and there is a dry and ventilated room. If it is stored for a long time, it should be checked frequently for anti-corrosion.
2. Clean the valve before installation and eliminate the defects during transportation.
3. During installation, it is necessary to carefully check whether the marks and nameplates on the valve meet the use requirements.
4. The lift type vertical disc check valve shall be installed on the vertical pipeline.
5. Lift type horizontal disc check valve shall be installed on horizontal pipeline.
6. Don't make the check valve bear weight in the pipeline. Large check valves should be supported independently, so that they are not affected by the pressure generated by the piping system.
7. When installing the check valve, special attention should be paid to the flow direction of the medium, so that the normal flow direction of the medium is consistent with the direction of the arrow indicated on the valve body, otherwise the normal flow of the medium will be cut off. The bottom valve shall be installed at the bottom of the water pump suction pipe.
8. The general lift check valve should be installed on the horizontal pipeline, while the vertical lift check valve and bottom valve are generally installed on the vertical pipeline, and the medium flows from bottom to top.